TELEPHONE CABLES
YR 100 V  VVT - F2  TPVF  TVVF - F2  SVV - F2 
ISYT1 - PTT278 s.e  YYSCH

Indoor Telephone Cable
Installation cable according to VDE 0815

Cable Make-Up

  • J-YY Single-wired conductor of plain copper wire, PVC-based core insulation, fur cores twisted to star quad, core colours according to VDE 0815, PVC-based outer scheath, RAL 7032

  • J-Y (ST) Y Like J-YY...BD but cores are twisted in pairs, cable core covered by a static screen of aluminium-clad plastic wire with copper conductor, PVC-based outer sheaath RAL 7032.

  • BMD brandmeldekabel is the same cable but with red PVC sheath, request for alarm system.

N° of double
cores
N° of star
quads
Approx. outside
diameter ca. mm
Copper
weight Kg/Km
Approx.
weight Kg/Km
J - YY
2 x 0,6
4
6
10
16
20
24
30
40
50
60
80
100
1
2
3
5
8
10
12
15
20
25
30
40
50
5,0
6,5
7,0
8,5
10,0
11,0
12,0
13,5
15,0
15,5
18,5
20,5
22,5
11,0
23,0
34,0
57,0
90,0
113,0
136,0
170,0
226,0
283,0
339,0
452,0
565,0
35
60
75
110
160
200
225
285
365
450
530
700
850
N° of double
cores
N° of star
quads
Approx. outside
diameter ca. mm
Copper
weight Kg/Km
Approx.
weight Kg/Km
J - Y ( ST ) Y...
  1 x 0,6
2
3
4
5
6
8
10
12
14
16
20
24
30
40
50
60
80
100
1 x 0,8
2
3
4
5
6
8
10
12
14
16
20
24
30
40
50
60
80
100
5,0
5,5
6,3
6,8
7,2
7,5
8;0
9,0
9,5
10;0
10,5
11;0
11,5
13,0
15,0
17,0
18,0
20,5
23,0
6,0
7,0
8,5
9,0
9,5
10,5
11,5
13,0
14,0
14,5
15,5
16,5
19,0
20,0
22,5
25,5
28,0
31,0
32,0
6,9
13;0
18;0
24,0
30,0
35,0
46,0
58,0
71,0
82,0
93,0
116,0
139,0
172,0
229,0
286,0
342,0
455,0
568,0
11,0
21,0
31,0
41,0
52,0
62,0
82,0
102,0
123,0
144,0
164,0
204,0
244,0
304,0
405,0
506,0
606,0
807,0
1008,0
30
40
50
60
70
80
90
110
130
145
160
190
220
280
350
430
500
640
850
40
60
80
100
120
140
170
220
250
280
320
380
460
560
710
900
1050
1400
1750

 

YR 100 V ( Adapted to VDE 0812 )

Construction
Solid copper conductor - PVC insulation -  PVC outer sheath
Application
For fixed installation as house wiring cable, on and under
plastering.

N° of cores and diameter ( mm ) Insulation thickness ( mm ) Outer sheath thickness ( mm ) Outer diameter approx. mm Copper weight Kg/Km Weight of cable approx. Kg/Km

YR 100 V

2 x 0,8
3 x 0,8
4 x 0,8
5 x 0,8
6 x 0,8
7 x 0,8
8 x 0,8
10 x 0,8
12 x 0,8
14 x 0,8
16 x 0,8
20 x 0,8
24 x 0,8
30 x 0,8
0,4
0,4
0,4
0,4
0,4
0,4
0,4
0,4
0,4
0,4
0,4
0,4
0,4
0,4
0,8
0,9
0,9
1,1
1,1
1,1
1,1
1,1
1,1
1,1
1,1
1,1
1,1
1,3
4,8
5,3
5,7
6,6
7,0
7,0
7,6
8,6
8,9
9,3
9,8
10,7
11,9
12,9
9,6
14,4
19,2
24
28,8
34
38
48
58
67
77
96
115
144
28
38
46
62
72
76
88
103
118
134
151
182
213
267

 

VVT - F2

Standard:  IEC 189-1 - IEC 189-2

Usage: Telephone cable for indoor installation
Inner conductor in Red Copper
Earth wire insulated in white PVC with double black ring
Enveloppe isolante en PVC
PVC Jacket (cat.F2 selon NBN C30-004)


N. of counductors Diameter of the earth wire

( mm )
Outer sheath thickness

 ( mm )
External diameter

± mm
Weight per Km

± Kg
1 x 3 x 0,6 (a)
1 x 4 x 0,6 (b)
3 x 2 x 0,6
4 x 2 x 0,6
6 x 2 x 0,6
8 x 2 x 0,6
10 x 2 x 0,6
14 x 2 x 0,6
20 x 2 x 0,6
26 x 2 x 0,6
30 x 2 x 0,6
40 x 2 x 0,6
50 x 2 x 0,6
100 x 2 x 0,6
-
0,4
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,2
1,2
1,2
1,4
1,4
1,4
1,8
4,5
5,0
5,5
6,5
7,0
8,5
9,0
9,5
11,5
12,5
13,5
15,0
16,5
23,5
25
35
45
55
70
100
115
135
190
230
280
360
425
870

 

TPVF

Usage: Telephone cable for indoor installation
Inner conductor in Red Copper
Insulated foil in PE
Aluminium-PE ribbon
Earth wire in tinned copper
PVC Jacket

N. of counductors Diameter of the earth wire

( mm )
Outer sheath thickness

  ( mm )
External diameter

± mm
Weight per Km

± Kg
1 x 2 x 0,6
2 x 2 x 0,6
3 x 2 x 0,6
4 x 2 x 0,6
5 x 2 x 0,6
6 x 2 x 0,6
8 x 2 x 0,6
10 x 2 x 0,6
12 x 2 x 0,6
15 x 2 x 0,6
20 x 2 x 0,6
30 x 2 x 0,6
40 x 2 x 0,6
50 x 2 x 0,6
60 x 2 x 0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,8
0,8
0,8
0,8
0,8
0,8
0,8
1,0
1,0
1,0
1,0
1,2
1,2
1,2
1,2
4,1
6,2
6,5
7,0
7,7
8,4
9,1
10,2
11,4
12,3
13,6
16,0
19,0
21,0
22,0
23
39
48
59
72
86
100
121
151
180
228
335
405
520
580

 

TVVF - F2

Usage: Telephone Cable for indoor istallation, with fire detection

Inner conductor in Red Copper
PVC Jacket (cat. F2 selon NBN C30-004)
Aluminium-PP foil stealth
Earth wire in tinned copper

N. of counductors Diameter of the earth wire

( mm )
Outer sheath thickness

  ( mm )
External diameter

± mm
Weight per Km

± Kg
1 x 2 x 0,6
1 x 4 x 0,6
3 x 2 x 0,6
4 x 2 x 0,6
5 x 2 x 0,6
6 x 2 x 0,6
8 x 2 x 0,6
10 x 2 x 0,6
12 x 2 x 0,6
14 x 2 x 0,6
16 x 2 x 0,6
20 x 2 x 0,6
0,4
0,4
0,4
0,4
0,4
0,4
0,4
0,4
0,6
0,6
0,6
0,6
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,2
1,2
4,6
5,0
6,0
6,4
6,8
7,0
7,6
8,8
9,0
9,5
10,3
11,0
30
40
50
60
70
80
90
110
130
150
160
190

 

SVV - F2 ( IEC 189-1 )

Usage: Signalling cable dor indoor installation

Inner conductor in Red Copper
PVC Jacket (cat. F2 selon NBN C30-004)

N. of counductors Diameter of the earth wire

( mm )
Outer sheath thickness

  ( mm )
External diameter

± mm
Weight per Km

± Kg
2 x 0,8
4 x 0,8
6 x 0,8
8 x 0,8
10 x 0,8
12 x 0,8
14 x 0,8
16 x 0,8
  0,5
0,6
0,6
0,7
0,9
1,0
1,0
1,0
4,0
5,0
6,0
6,5
8,0
8,5
9,0
9,5
20
35
50
66
94
110
115
130

 

Indoor telephone Cables

French installation cable for industrial and domestic usage on telecommunications and informations processing systems. These cables are suitables for installation in dry and moist operating areas in buildings. Our cables is produced according the NFC C 93-529 norms for the SYT1 series and the NFC 93-526/527/528 for the PTT 278 series.

Section
mm
Copper weight 
Kg/Km
Outs. diameter approx. 
mm
Cable weight approx.
Kg/Km
Poids
Kg/Km
SYT1
1 x 2 x 0,5
2 x 2 x 0,5
3 x 2 x 0,5
5 x 2 x 0,5
7 x 2 x 0,5
10 x 2 x 0,5
15 x 2 x 0,5
21 x 2 x 0,5
30 x 2 x 0,5
42 x 2 x 0,5
56 x 2 x 0,5
1 x 2 x 0,6
2 x 2 x 0,6
3 x 2 x 0,6
5 x 2 x 0,6
7 x 2 x 0,6
10 x 2 x 0,6
15 x 2 x 0,6
21 x 2 x 0,6
30 x 2 x 0,6
42 x 2 x 0,6
56 x 2 x 0,6
1 x 2 x 0,9
2 x 2 x 0,9
3 x 2 x 0,9
5 x 2 x 0,9
7 x 2 x 0,9
10 x 2 x 0,9
15 x 2 x 0,9
21 x 2 x 0,9
30 x 2 x 0,9
42 x 2 x 0,9
56 x 2 x 0,9
5,8
10,84
16
25
34,47
49
74
105
146
205
286
6,9
13
18
30
41,36
58
87
122
172
240
320
11
21
31
52
71
102
154
214
304
425
567
5
6
6,5
7
8
9
10,5
12
14
15
16,5
5,5
6,5
7
8
8,5
10
11,5
12,5
15
16,5
18
6,5
8,5
9
10,5
12
13,5
15
17
22,5
23
25
22
31
46
61
76
99
140
178
241
316
402
23
33
39
63
78
101
138
190
251
337
433
35
64
79
114
155
206
287
383
522
708
922
20
29
34
46
63
81
109
150
197
259
329
622
23
33
39
63
78
101
138
190
251
337
433
825
6,9
13
18
30
42
58
87
122
172
PTT 278 S.E.
2 x 2 x 0,6
4 x 2 x 0,6
11
23
5,2
6,2
21
45
240
320

 

N° of cores and diameter
( mm )
Outer diameter approx. 
( mm )
Copper weight 
Kg/Km
Weight of cable approx. 
Kg/Km
YYSCH
2 x 0,6
3 x 0,6
4 x 0,6
5 x 0,6
6 x 0,6
10 x 0,6
16 x 0,6
26 x 0,6
5,6
8,4
11,2
14,0
16,8
28,0
45,0
73,0
3,0
3,2
3,4
3,7
4,0
6,0
6,8
8,2
15
18
21
26
31
53
75
110

Cables and Cables
Tel:+86-574-56126039/52 Fax:+86-574-56126053
Copyright © 2007-2008 Cables and Cables