TELEPHONE CABLES
YR
100 V VVT
- F2 TPVF
TVVF - F2
SVV - F2
ISYT1
- PTT278 s.e YYSCH
|

|
|
Indoor Telephone Cable
Installation cable according to VDE 0815
Cable Make-Up
-
J-YY Single-wired conductor of plain copper wire, PVC-based
core insulation, fur cores twisted to star quad, core colours according to VDE 0815, PVC-based outer scheath, RAL 7032
-
J-Y (ST) Y Like J-YY...BD but cores are twisted in pairs, cable
core covered by a static screen of aluminium-clad plastic wire with copper conductor, PVC-based outer sheaath RAL 7032.
-
BMD brandmeldekabel is the same cable but with red PVC
sheath, request for alarm system.
|
N° of double
cores |
N° of star
quads |
Approx. outside
diameter ca. mm |
Copper
weight Kg/Km |
Approx.
weight Kg/Km |
|
J - YY |
2 x 0,6
4
6
10
16
20
24
30
40
50
60
80
100 |
1
2
3
5
8
10
12
15
20
25
30
40
50 |
5,0
6,5
7,0
8,5
10,0
11,0
12,0
13,5
15,0
15,5
18,5
20,5
22,5 |
11,0
23,0
34,0
57,0
90,0
113,0
136,0
170,0
226,0
283,0
339,0
452,0
565,0 |
35
60
75
110
160
200
225
285
365
450
530
700
850 |
N° of double
cores |
N° of star
quads |
Approx. outside
diameter ca. mm |
Copper
weight Kg/Km |
Approx.
weight Kg/Km |
|
J - Y
( ST ) Y... |
|
|
1 x 0,6
2
3
4
5
6
8
10
12
14
16
20
24
30
40
50
60
80
100
1 x 0,8
2
3
4
5
6
8
10
12
14
16
20
24
30
40
50
60
80
100 |
5,0
5,5
6,3
6,8
7,2
7,5
8;0
9,0
9,5
10;0
10,5
11;0
11,5
13,0
15,0
17,0
18,0
20,5
23,0
6,0
7,0
8,5
9,0
9,5
10,5
11,5
13,0
14,0
14,5
15,5
16,5
19,0
20,0
22,5
25,5
28,0
31,0
32,0 |
6,9
13;0
18;0
24,0
30,0
35,0
46,0
58,0
71,0
82,0
93,0
116,0
139,0
172,0
229,0
286,0
342,0
455,0
568,0
11,0
21,0
31,0
41,0
52,0
62,0
82,0
102,0
123,0
144,0
164,0
204,0
244,0
304,0
405,0
506,0
606,0
807,0
1008,0 |
30
40
50
60
70
80
90
110
130
145
160
190
220
280
350
430
500
640
850
40
60
80
100
120
140
170
220
250
280
320
380
460
560
710
900
1050
1400
1750 |
|

|
|
YR
100 V ( Adapted to VDE 0812
)
Construction
Solid copper conductor - PVC insulation - PVC outer sheath
Application
For fixed installation as house wiring cable, on and under
plastering. |
| N° of cores and
diameter ( mm ) |
Insulation
thickness ( mm ) |
Outer sheath
thickness ( mm ) |
Outer diameter
approx. mm |
Copper
weight Kg/Km |
Weight of cable
approx. Kg/Km |
|
YR
100 V |
2 x 0,8
3 x 0,8
4 x 0,8
5 x 0,8
6 x 0,8
7 x 0,8
8 x 0,8
10 x 0,8
12 x 0,8
14 x 0,8
16 x 0,8
20 x 0,8
24 x 0,8
30 x 0,8 |
0,4
0,4
0,4
0,4
0,4
0,4
0,4
0,4
0,4
0,4
0,4
0,4
0,4
0,4 |
0,8
0,9
0,9
1,1
1,1
1,1
1,1
1,1
1,1
1,1
1,1
1,1
1,1
1,3 |
4,8
5,3
5,7
6,6
7,0
7,0
7,6
8,6
8,9
9,3
9,8
10,7
11,9
12,9 |
9,6
14,4
19,2
24
28,8
34
38
48
58
67
77
96
115
144 |
28
38
46
62
72
76
88
103
118
134
151
182
213
267 |
|
VVT
- F2 |
|
Standard: IEC 189-1
- IEC 189-2
Usage: Telephone cable for indoor installation Inner conductor in Red Copper
Earth wire insulated in white PVC with double black ring
Enveloppe isolante en PVC
PVC Jacket (cat.F2 selon NBN C30-004)
|
| N. of counductors |
Diameter of the earth wire
( mm ) |
Outer sheath thickness
( mm ) |
External diameter
± mm |
Weight per Km
± Kg |
1 x 3 x 0,6 (a)
1 x 4 x 0,6 (b)
3 x 2 x 0,6
4 x 2 x 0,6
6 x 2 x 0,6
8 x 2 x 0,6
10 x 2 x 0,6
14 x 2 x 0,6
20 x 2 x 0,6
26 x 2 x 0,6
30 x 2 x 0,6
40 x 2 x 0,6
50 x 2 x 0,6
100 x 2 x 0,6 |
-
0,4
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6 |
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,2
1,2
1,2
1,4
1,4
1,4
1,8 |
4,5
5,0
5,5
6,5
7,0
8,5
9,0
9,5
11,5
12,5
13,5
15,0
16,5
23,5 |
25
35
45
55
70
100
115
135
190
230
280
360
425
870 |
|
TPVF |
|
Usage: Telephone cable for indoor installation
Inner conductor in Red Copper
Insulated foil in PE
Aluminium-PE ribbon
Earth wire in tinned copper
PVC Jacket |
| N. of counductors |
Diameter of the earth wire
( mm ) |
Outer sheath thickness
( mm ) |
External diameter
± mm |
Weight per Km
± Kg |
1 x 2 x 0,6
2 x 2 x 0,6
3 x 2 x 0,6
4 x 2 x 0,6
5 x 2 x 0,6
6 x 2 x 0,6
8 x 2 x 0,6
10 x 2 x 0,6
12 x 2 x 0,6
15 x 2 x 0,6
20 x 2 x 0,6
30 x 2 x 0,6
40 x 2 x 0,6
50 x 2 x 0,6
60 x 2 x 0,6 |
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6 |
0,8
0,8
0,8
0,8
0,8
0,8
0,8
1,0
1,0
1,0
1,0
1,2
1,2
1,2
1,2 |
4,1
6,2
6,5
7,0
7,7
8,4
9,1
10,2
11,4
12,3
13,6
16,0
19,0
21,0
22,0 |
23
39
48
59
72
86
100
121
151
180
228
335
405
520
580 |
|
TVVF
- F2 |
|
Usage: Telephone Cable for indoor istallation, with fire detection
Inner conductor in Red Copper
PVC Jacket (cat. F2 selon NBN C30-004)
Aluminium-PP foil stealth
Earth wire in tinned copper |
| N. of counductors |
Diameter of the earth wire
( mm ) |
Outer sheath thickness
( mm ) |
External diameter
± mm |
Weight per Km
± Kg |
1 x 2 x 0,6
1 x 4 x 0,6
3 x 2 x 0,6
4 x 2 x 0,6
5 x 2 x 0,6
6 x 2 x 0,6
8 x 2 x 0,6
10 x 2 x 0,6
12 x 2 x 0,6
14 x 2 x 0,6
16 x 2 x 0,6
20 x 2 x 0,6 |
0,4
0,4
0,4
0,4
0,4
0,4
0,4
0,4
0,6
0,6
0,6
0,6 |
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,2
1,2 |
4,6
5,0
6,0
6,4
6,8
7,0
7,6
8,8
9,0
9,5
10,3
11,0 |
30
40
50
60
70
80
90
110
130
150
160
190 |
|
SVV
- F2 ( IEC 189-1
) |
|
Usage: Signalling cable dor indoor installation
Inner conductor in Red Copper
PVC Jacket (cat. F2 selon NBN C30-004) |
| N. of counductors |
Diameter of the earth wire
( mm ) |
Outer sheath thickness
( mm ) |
External diameter
± mm |
Weight per Km
± Kg |
2 x 0,8
4 x 0,8
6 x 0,8
8 x 0,8
10 x 0,8
12 x 0,8
14 x 0,8
16 x 0,8 |
|
0,5
0,6
0,6
0,7
0,9
1,0
1,0
1,0 |
4,0
5,0
6,0
6,5
8,0
8,5
9,0
9,5 |
20
35
50
66
94
110
115
130 |
|
Indoor telephone Cables |
|
French installation cable for industrial and domestic usage on telecommunications and informations processing systems. These cables are suitables for installation in dry and moist operating areas in buildings. Our cables is produced according the NFC C 93-529 norms for the SYT1 series and the NFC 93-526/527/528 for the PTT 278 series. |
Section
mm |
Copper
weight
Kg/Km |
Outs. diameter
approx.
mm |
Cable weight approx.
Kg/Km |
Poids
Kg/Km |
| SYT1 |
1 x 2 x 0,5
2 x 2 x 0,5
3 x 2 x 0,5
5 x 2 x 0,5
7 x 2 x 0,5
10 x 2 x 0,5
15 x 2 x 0,5
21 x 2 x 0,5
30 x 2 x 0,5
42 x 2 x 0,5
56 x 2 x 0,5
1 x 2 x 0,6
2 x 2 x 0,6
3 x 2 x 0,6
5 x 2 x 0,6
7 x 2 x 0,6
10 x 2 x 0,6
15 x 2 x 0,6
21 x 2 x 0,6
30 x 2 x 0,6
42 x 2 x 0,6
56 x 2 x 0,6
1 x 2 x 0,9
2 x 2 x 0,9
3 x 2 x 0,9
5 x 2 x 0,9
7 x 2 x 0,9
10 x 2 x 0,9
15 x 2 x 0,9
21 x 2 x 0,9
30 x 2 x 0,9
42 x 2 x 0,9
56 x 2 x 0,9 |
5,8
10,84
16
25
34,47
49
74
105
146
205
286
6,9
13
18
30
41,36
58
87
122
172
240
320
11
21
31
52
71
102
154
214
304
425
567 |
5
6
6,5
7
8
9
10,5
12
14
15
16,5
5,5
6,5
7
8
8,5
10
11,5
12,5
15
16,5
18
6,5
8,5
9
10,5
12
13,5
15
17
22,5
23
25 |
22
31
46
61
76
99
140
178
241
316
402
23
33
39
63
78
101
138
190
251
337
433
35
64
79
114
155
206
287
383
522
708
922 |
20
29
34
46
63
81
109
150
197
259
329
622
23
33
39
63
78
101
138
190
251
337
433
825
6,9
13
18
30
42
58
87
122
172 |
| PTT
278 S.E. |
2 x 2 x 0,6
4 x 2 x 0,6 |
11
23 |
5,2
6,2 |
21
45 |
240
320 |
|

|
N° of cores and diameter
( mm ) |
Outer diameter
approx.
( mm ) |
Copper
weight
Kg/Km |
Weight of cable
approx.
Kg/Km |
| YYSCH |
2 x 0,6
3 x 0,6
4 x 0,6
5 x 0,6
6 x 0,6
10 x 0,6
16 x 0,6
26 x 0,6 |
5,6
8,4
11,2
14,0
16,8
28,0
45,0
73,0 |
3,0
3,2
3,4
3,7
4,0
6,0
6,8
8,2 |
15
18
21
26
31
53
75
110 |
|